144 JOURNAL OF THE SOCIETY OF COSMETIC CHEMISTS RESULTS PATCH TEST Compared to the untreated reference, application of the Hill Top chamber, alone or with water, did not cause any effect on the selected skin parameters. As a consequence, we can compare the results of product application with the values obtained after application of the Hill Top chamber with water alone, considering the latter as blank. We chose this blank because it corresponds better to the immersion in water alone, used also in the hand/forearm immersion protocol. The latter permits a more realistic comparison be- tween the two test procedures (comparison between the patch test and the hand/forearm immersion test). When evaluating the kinetics obtained after application of the three products, a marked increase in TEWL values is detected for the three test products (see Table I). The strongest increase is observed for N28, a weaker increase for ASV, and the weakest increase for Plantaren. Values remain increased up to 48 hours after removal of the second patch. At that time, a similar rank order is detected with highest values for N28, lower values for ASV, and the lowest values for Plantaren. The MANOVA procedure detected statistically significant changes between the kinetics of the three applied prod- ucts when compared with the Hill Top Chamber containing water. Analysis of the global response (ZTEWL) revealed similar results: the strongest response was observed on the skin side challenged with N28, lower values for ASV, and the lowest values for Plantaren (see Table IV). The ANOVA procedure detected significant differ- ences between the tested products and the control equal statistical differences were observed between N28 and the other two test products (ASV and Plantaren, respec- tively). The capacitance values were decreased after repetitive application of the different test solutions, indicating a dehydration of the stratum corneum (see Table II). Differences between the kinetics of the three products were less clear. However, at the last interval, the lowest values were detected for N28. Statistically, we were able to detect a signifi- cant difference between the kinetics of the different test products and the control. The global response (Y'•4yd) delivered similar results, the lowest values for N28, followed by Plantaren and ASV, respectively (see Table IV). Again the responses to the three evaluated products were significantly different from that of the control. No differences were detected when comparing the global responses of the three products. Skin redness, as evaluated by the a* color value, demonstrated equally a marked increase after application of the three products (see Table III). N28 showed the strongest increase, a weaker increase was noticed for ASV, and the weakest response was detected for Plantaren. Values at 48 hours after the end of the patch test did not return to baseline. At that time, a similar redness rank order was detected: N28 ASV Plantaren. The kinetics of the applied products differed significantly from the application of water alone. The global a* response (Y'a*) showed the same rank order. Significant differences were detected when comparing the Y,a. values calculated for the different test products with the Y,•. values calculated for the reference (see Table IV).
TWO TESTS OF DETERGENT IRRITANCY 145 +1 +1 +1 +1 +1
Previous Page Next Page