MICROBIAL QUALITY CONTROL 77 Figure 2. Uv sterilizer Table III Sterilization of Cellulose Gums by Ethylene Oxide Gas' Lot Number Microorganism Count (cells/g) Untreated EO Gas Treatment 23666 1.6 X 10 .0 0 26264 1.2 X 10 • 0 'EO gas treatment conditions: Gas density-----20 per cent (diluted with carbon dioxide) Pressure, 1.0 Kg/cn½ Temperature, 50-55øC Time, 4 hours. microporous filter mounted on the air inlet. This filter has the capability to filter out any foreign matter larger than 0.08 /•m, thereby preventing or- ganisms from entering the u,fit. The storage tank is also equipped with a microporous filter and as is shown in Fig. 3. B. Microbially Free Condition During Filling Operation 1. Clean Room: It is well known that a clean room must be utilized in order to obtain a microbially free condition during the filling operation of cosmetics and pharmaceuticals. According to the results of this investigation,
78 JOURNAL OF THE SOCIETY OF COSMETIC CHEMISTS Table IV Sterilizing Method used for the manufacturing Equipment Method used to Prevent Contmni- Equipn,e,,t Sterilizing Method nation Caused by Air Supply Kettles Hot water sterilization Microporous filter Disinfectant solution • (in joints) Pipes Ilot water sterilization Disinfectant solution a (in joints) Cooling equipments Hot water sterilization Storage tanks After hot water sterilization, drying by microbially free filtered air Didnfectant solution a (in joints) Microporous filter "The disinfectant solution used for sterilization was chlorhexidine in 70 per cent alcoholic solution. a clean room as is shown in Fig. 4 is satisfactory. The room is 10.8 m x 5.4 m wide and 2.6 m in height. This clean room is equipped with a horizontal laminar flow system. The air is passed through high efficiency particulate fil- ters and enters the room from the right side, passes through the clean room and is discharged at the exhaust grill arranged on the left side wall. Entry to the room is from the left side through the air shower and in order to limit entry of microorganisms, every person or large material and equip- ment entering the room must be exposed for a minirotan of 30 sec to an air shower, which has a 15 m/sec wind velocity. This can be seen in Fig. 5. One can notice on the upper side of the room, two pass boxes, which are used to bring packaging material into the room. There is also an opening for taking out the filled products. The position of the filling machines is near the filtering air wall, where there is the least degree of contamination, while the storage tank, which is a closed system and ]east prone to contamination, is arranged nearest the air discharge grill. In between the filter and the storage tank, the materials (such as collapsible metal tubes) and working personnel are located. To maintain the constant efficiency of the clean room, the number of working personnel entering the room is limited to a minimum. Before being brought into the clean room, material and machinery are sterilized, and the whole facility is checked at constant intervals for microbial contamination. 2. Operation: To prevent microbial contamination in the clean room, after it is sterilized, all filling equipment is transported through the air shower tunnel into the clean room. Table V shows the sterilizing method used for this equipment. To impede contamination in the clean room, all working personnel (before they enter the room) must wear sterile dust-free garments complete with head
Purchased for the exclusive use of nofirst nolast (unknown) From: SCC Media Library & Resource Center (library.scconline.org)