512 JOURNAL OF THE SOCIETY OF COSMETIC CHEMISTS 3. photograph the same identical areas, before and after treatment, as a function of time, and by following the same identical area, avoid some of the problems of hetcrogeneity from point to point 4. make large montages, rather than randomly selected pictures so it would be obvious a large enough area was being photographed 5. quantify the resulting images either manually or through the use of an image analyzing computer (such as a Quantimet) 6. correlate the results, quantitatively as well as qualitatively, with known clinical conditions. The purpose of this paper, therefore, is to describe some of the methods we have developed for this purpose, to present the clinical basis for justifying this approach, and to show how the resulting data is presently being used to dem- onstrate efficacy and document advertising claims. EXPERI1VIENTAL A. Preparation o• Negative Replicas RTV-11 sfiicon resin is acceptable for making the negative replicas, al- though we find that better results are obtained with the high molecular weight fraction removed and when an absolute minimum of catalyst is used to setup the resin. Certain silicone-compatible surface active agents (such as "Aero- sol OT,"*) seem to impart better release characteristics and may have their maximum benefit when replicating particularly rough skin (such as psoriatie subiects). B. Conversion o[ Negative Replicas to Positive Replicas Almost any thermoplastic resin can be used for this purpose, but we prefer fine spray-dried or asopolymerized polyolefin "bead" polymer. After the posi- tive replica is completed, it is metallized to make the replica surface conduc- tive to prevent sample charging in the electron beam. C. Preparation o[ Replica Cross-Sections For replica cross-section work, the positive replicas are diamond knife- trimmed, using a duPont/Sorvall MT2-B Diamond Knife Ultramicrotome.t The knife speed and angle must be adjusted for minimum chatter and thin- nest sections (even though the sections are not important) as these are the conditions for obtaining the best undistorted and unsmeared cross-sections. Unfortunately, the sorer resins yield the best detail in the positives hence, we sometimes must do the sectioning in a cryostage at liquid nitrogen tem- *American Cyanamid Co., Stamford, CT. rE. I. dupont de Nemours and Co., Inc., Wilmington, DE 19898.
SCANNING ELECTRON MICROSCOPY 513 peratures as a means of minimizing smearing and preserving the cross-section- al edge. We have not been successful using glass knives for this purpose. D.SEM The work described in this paper was done on a JEOL Model #JSM-U3 SEM.* We have found this equipment to be particularly well-suited for this type of work for several reasons: (1) it can be modified without too much dif- ficulty to provide a virtually distortion-free image in the 15 to 20 X range, an absolute necessity for putting together distortion free montages (2) it has an extremely flexible goniometer stage, with all of the degrees of freedom neces- sary to relocate the same identical areas of a replica without exceptional dif- ficulty and (3) the electronic stability of the instrument is such that micro- graphs can be taken without discernable drift in brightness or contrast, an ex- tremely important feature xvhen montages are being made. The most important aspect of our procedure is that every successive replica in a series is done on the very same identical area, same tilt, same magnifi- cation, in short, every aspect of the images are identical. We have eliminated any chance that a particular feature of the results might be due to the way the microscopy was done rather than due to real changes on the skin sur- face. This also means, therefore, that all microscopy, which is done generally in the form of large montages, is clearly from the same identical areas and this fact is so obvious, that even a nonmicroscopy-oriented observer would realize it. E. Quantitative Image Analysis All image analysis was done on a Quantimet 720B Image Analysing Com- puter equipped with the automatic detector, optical and epidiascope input modes, and classifier-collector modules with direct teletype output. RESULTS An example of what one can typically obtain is shown on Fig. 1. This is an area from the back of the hand of a young female subject in her mid-twenties, and the microscopy was originally done as a montage at 100 X from the scanning electron microscope (but which was reduced for publication). The original individual fields that make up the montage can still be seen. The "hill and valley" type of topography is "normal," particularly for young- er subjects. The one major exception is what is sometimes called the "cobble- stone" texture and an example of it is shown in Fig. 2. The term "cobblestone" *Jeol (USA), Inc., Medford, MA.
Previous Page Next Page