INSTRUMENTAL ASSESSMENT OF SKIN 267 (5) M. B. Finkey and D. M. Crowe, The use ofevaporimetry to evaluate soap induced irritation on the face, Bioeng. Skin, 4, 311-321 (1988). (6) P. T. Sharko, R. I. Murahata, J. J. Leyden, and G. L. Grove, Arm wash with instrumental eval- uation--A sensitive technique for differentiating the irritation potential of personal washing prod- ucts, 48th Annual Meeting of the American Academy of Dermatology (abstr.) (1989). (7) J. Nucci, Measurement of skin-surface viscoelasticity for claim support and product development, Cosmet. Toiletr., 104(3), 47-51 (1989). (8) D. L. Miller, In vivo instrumentation in clinical dermal testing, Cosmet. Toiletr., 101, 57-61 (1986). (9) R. M. Dahlgren, M. F. Lukacovic, S. E. Michaels, and M. O. Visscher, "Effects of Bar Soap Constituents on Product Mildness," in Proceedings of the Second World Conference on Detergents, Mon- treux, Switzerland, A. R. Baldwin, Ed. (American Oil Chemists Society, 1987), pp. 127-134. (10) G. L. Grove, Design of studies to measure skin care product performance, Bioeng. Skin, 3(4), 359-373 (1987). (11) R. O. Potts, Stratum corneum hydration: Experimental techniques and interpretations of results. J. Soc. Cosmet. Chem,, 37, 9-33 (1986). (12) G. E. Nilsson, Measurement of water exchange through skin. Med. Biol. Eng. Cornput., 15, 209- 218, (1977). (13) E. P. Pittz, Non-destructive methods for evaluation of cutaneous irritancy, Cosmet. Toiletr., 98, 51-65, (1983). (14) R. I. Murahata, S. A. O. Hing, H. I. Maibach, and J. R. Roheim, The use of a microwave probe to evaluate the hydration of human stratum corneum in vivo, Bioeng. Skin, 2, 235-247 (1986). (15) D. L. Miller, Impedance and water loss measurements, Biophysical Methods for Skin Characterisation Symposium, New York (abstr.) (1986). (16) D. Wilson, E. Berardesca, and H. I. Maibach, In vivo transepidermal water loss and skin surface hydration in assessment of moisturization and soap effects, Int. J. Cosmet. Sci,, 10(5), 201-211 (1988). (17) M.D. Batt and E. Fairhurst, Hydration of the stratum corneum, Int. J. Cosmet. Sci., 8(6), 253-264 (1986). (18) R. A. Tupker, J. Pinnagoda, P. J. Coenraads, and J.P. Nater, The influence of repeated exposure to surfactants on the human skin as determined by transepidermal water loss and visual scoring, Contact Dermatitis, 20, 108-114 (1989). (19) M. Wu, D. J. Yee, and M. E. Sullivan, Effect of a skin moisturizer on the water distribution on human stratum corneum, J. Invest. Dermatol., 81, 446-448 (1983). (20) J. L. Leveque, J. C. Garson, and J. de Rigal, Transepidermal water loss from dry and normal skin. J. Soc. Cosmet. Chem., 30, 333-343 (1979). (21) J. Pinnagoda, R. A. Tupker, P. J. Coenraads, and J. P. Nater, Comparability and reproducibility of the results of water loss measurements: A study of 4 evaporimeters, Contact Dermatitis, 20(4), 241-246 (1989). (22) D. R. Wilson and H. Maibach, "Transepidermal Water Loss: A Review," in Cutaneous Investigation in Health and Disease. Noninvasive Methods and Instrumentation, J. L. Leveque, Ed. (Marcel Dekker, New York and Basel, 1989), pp. 113-133. (23) J. Pinnagoda, R. A. Tupker, T. Agner, and J. Serup, Guidelines for transepidermal water loss (TWEL) measurement. A report from the standardization group of the European Society of Contact Dermatitis, Contact Dermatitis, 22, 164-178 (1990). (24) S. W. Babulak, L. D. Rhein, D. D. Scala, F. A. Simion, and G. L. Grove, Quantitation of ery- thema in a soap chamber test using the Minolta Chroma (Reflectance) Meter: Comparison of instru- mental results with visual assessments, J. Soc. Cosmet. Chem., 37, 475-479 (1986). (25) S. Freeman and H. Maibach, Study of irritant contact dermatitis produced by repeat patch test with sodium lauryl sulfate and assessed by visual methods, transepidermal water loss, and laser Doppler velocimetry, J, Am. Acad. Dermatol., 19(3), 496-502 (1988). (26) J. H. Hassing, J. P. Nater, and E. Bleumink, Irritancy of low concentrations of soap and synthetic detergents as measured by skin water loss, Dermatologica, 164, 314-321 (1982). (27) T. Agner and J. Serup, Skin reactions to irritants assessed by non-invasive bioengineering methods, Contact Dermatitis, 20, 352-359 (1989). (28) P. G. M. Van der Valk, J. P. Nater, and E. Bleumink, Skin irritancy of surfactants as assessed by water vapor loss measurements, J. Invest. Dermatol., 82, 291-293 (1984). (29) R. A. Tupker, J. Pinnagoda, P. J. Coenraads, H. Kerstholt, and J. P. Nater, Evaluation of hand
268 JOURNAL OF THE SOCIETY OF COSMETIC CHEMISTS (37) cleansers: Assessment of composition, skin compatibility by transepidermal water loss measurements, and cleansing power, J. Soc. Cosmet. Chem., 40, 33-39 (1989). (30) P. G. M. Van der Valk, M. C. Crijns, J. P. Nater, and E. Bleumink, Skin irritancy of commercially available soap and detergent bars as measured by water vapour loss, Dermatosen, 32, 87-90 (1984). (31) R. I. Murahata, D. M. Crowe, and J. R. Roheim, The use of transepidermal water loss to measure and predict the irritation response to surfactants, Int. J. Cosmet. Sci., 8, 225-231 (1986). (32) P. G. M. Van der Valk, M. H. Kruis-de Vries, J.P. Nater, E. Bleumink, and M. C. J. M. De Jong, Eczematous (irritant and allergic) reactions of the skin and barrier function as determined by water vapour loss, Clin. Exp. Dermatol., 10, 185-193 (1985). (33) J. L. Leveque and J. De Rigal, Impedance methods for studying skin moisturization, J. Soc. Cosmet. Chem., 34, 419-428 (1983). (34) A. W. Fulmer and G. J. Kramer, Stratum corneum lipid abnormalities in surfactant-induced dry scaly skin, J. Invest. Dermatol., 86(5), 598-602 (1986). (35) H. Tagami, Y. Kanamaru, K. Inoue, S. Suehisa, F. Inoue, K. Iwatsuki, K. Yoshikuni, and M. Yamada, Water sorption-desorption test of the skin in vivo for functional assessment of the stratum corneum, J. Invest. Dermatol., 78, 425-428 (1982). (36) H. Tagami, "Impedance Measurement for Evaluation of the Hydration State of the Skin Surface," in Cutaneous Investigation in Health and Disease. Noninvasive Methods and Instrumentation, J. L. Leveque, Ed. (Marcel Dekker, New York and Basel, 1989), pp. 79-111. D. C. Salter, "Quantifying Skin Disease and Healing In Vivo Using Electrical Impedance Measurements," in Non-Invasive Physiological Measurements, P. Rolfe, Ed. (Academic Press, New York, 1979), Vol I., pp. 21-64. (38) G. Imokawa, S. Akasaki, A. Kawamata, S. Yano, and N. Takaishi, Water-retaining function in the stratum corneum and its recovery properties by synthetic pseudoceramides, J. Soc. Cosmet. Chem., 40, 273-285 (1989). (39) S. L. Jacques, A linear measurement of the water content of the stratum corneum of human skin using a microwave probe, IEEE Eng. Med. Biol. Soc. Conf., 180-182 (1979). (40) S. L. Jacques, D. Yeung, S. Nacht, I. H. Blank, and S. DeGirolamo, In vivo changes in skin surface water content, transepidermal water loss and mechanical properties with environmental relative humidity, Bioeng. Skin, 1(3), 260 (abstr.)(1984). (41) R. O. Potts, In vivo measurement of water content of the stratum corneum using infrared spectros- copy: A review, Cosmet. Toiletr., 100(10), 27-31 (1985). (42) P. Walling, Principal component analysis of moisture in the skin by near infrared reflectance analysis, Seventeenth Annual Meeting of the Federation of Analytical Chemistry and Spectroscopy Societies, Cleveland, Ohio (abstr.) (1990). (43) V. H. W. Mak, R. O. Potts, and R. H. Guy, Oleic acid concentration and effect in human stratum corneum: Non-invasive determination by attenuated total reflectance infrared spectroscopy in vivo, J. Controlled Release, 12, 67-75 (1990). (44) T. Kai, V. H. W. Mak, R. O. Potts, and R. H. Guy, Mechanism of percutaneous penetration enhancement: Effect of n-alkanols on the permeability barrier of hairless mouse skin, J. Controlled Release, 12, 103-112 (1990). (45) A. Rosencwaig, Photoacoustic spectroscopy of biological materials, Science, 181, 657-658 (1973). (46) M. A. Steinmetz and T. Adams, "Epidermal Water and Electrolyte Content and the Thermal, Electrical and Mechanical Properties of Skin," in Bioengineering and the Skin, R. Marks and P. A. Payne, Eds. (MTP Press Limited, Lancaster, UK, 1981), pp. 197-213. (47) H. C. Korting, M. Kober, M. Meuller, and O. Braun-Falco, Influence of repeated washing with soap and synthetic detergent on pH and resident flora of forehead and forearm, Acta Derm. Venereol. (Stockh), 67, 41-47 (1987). (48) R. R. Wickett and C. M. Trobaugh, Personal care products: Effects on skin surface pH, Cosmet. Toilerr., 105, 41-46 (1990). (49) E. Berardesca and H. I. Maibach, Bioengineering and the patch test, Contact Dermatitis, 18, 3-9 (1988). (50) P. Agache, I. Girardot, and J. C. Bernengo, "Optical Properties of the Skin," in Cutaneous Investi- gation in Health and Disease. Noninvasive Methods and Instrumentation, J. L. Leveque, Ed. (Marcel Dekker, New York and Basel, 1989), pp. 241-274. (51) D. M. Crowe, M. S. Willard, and R. I. Murahata, Quantitation of erythema by reflectance spec- troscopy, J. Soc, Cosmet. Chem., 38, 451-455 (1987). (52) G. E. Nilsson, E.G. Salerud, T. Tenland, P. A. Oberg, and J. E. Wahlberg, Laser Doppler
Previous Page Next Page