JOURNAL OF COSMETIC SCIENCE 128 The principle of the pendulum fi lm hardness test is based on the fact that the amplitude of oscillations of a pendulum rocking on a sample decreases more rapidly the softer the fi lm. The tester was set up to measure the number of oscillations. The factor-properties relationship regarding fi lm formation was tested with regard to the following factors: pH, temperature, presence of surfactant, and pigment dispersion since these are common factors involved in mascara manufacture. To determine the effect of temperature, Samples A, B, C, D, E and G were heated to 50°C cooled to 25°C, then drawn down as described above. Sample F was heated to 40°C, cooled to 25°C, then drawn down. To determine the effect of surfactant, the samples were heated as described above and mixed with 0.5% of surfactant. Two surfactants were employed: one with an HLB of 17, the other with an HLB of 4. The samples were cooled to 25°C and drawn down. To determine the effect of pigment, 5% of black iron oxide was added to the fi lm former and mixed under high shear at 2000 rpm for 15 minutes at room temperature, then drawn down. To determine the effect of pH, Samples F and G were adjusted to between pH 7 and 8 with isostearic acid and triethanolamine, respectively. EVALUTION OF POLYMERS FOR MASCARA APPLICATION A conventional mascara (O/W system) was prepared using the same amount of each poly- mer. A total of 7 mascara samples were prepared. The samples were fi lled in the same pack with the same applicator and applied to human lashes in a consistent manner with 30 strokes. Digital images of the eyelashes were taken and analyzed. The fi nal judgment on product performance included lash image analysis and panelists’ perception of product attributes. RESULTS AND DISCUSSION The changes in fi lm hardness are presented in Figure 2–8. In terms of the fi lm hardness of the neat polymer, Sample A (Figure 2) was the hardest and Sample E (Figure 6) was the softest, but that changed with the different factors. Regarding the effect of temperature, for almost all heated polymers, the hardness was lower than that of the neat polymer. Only Sample G exhibited an increase in fi lm hardness, which seemed brought about by the temperature. Overall, the fi lm-forming properties of Sample E (Figure 6) were in line with the fi lm hardness of the untreated polymer. Samples C and D showed modifi cation of fi lm hard- ness compared to the untreated state (Figure 4 and 5). The addition of pigment didn’t signifi cantly infl uence the hardness of Samples E and F, while Sample A, B, C, and D exhibited a reduction in fi lm hardness. Interesting functional properties were observed with Sample G (Figure 8), however. As mentioned above the fi lm hardness of this polymer signifi cantly increased under the infl uence of temperature. The same trend was observed under the infl uence of surfactants and pigment. The hardness of the fi lm declined at least by half when the pH was adjusted to neutral (Figure 10).
2008 TRI/PRINCETON CONFERENCE 129 Figure 2. Sample A (styrene acrylates copolymer, microemulsion). Figure 3. Sample B (acrylates copolymer, solution). Figure 4. Sample C (polyurethane, microemulsion).
Previous Page Next Page