INTERPRETATIONS AND APPLICATIONS OF FLOW MEASUREMENTS 603 where k=k•/k2 and ka are instrument constants. Since U and./' are shear independent C is again equal to 1. Since the shearing stress in a capillary-tube viscometer is proportional to the diameter, r is zero at the center and approaches zero near the center of the capillary. A Bingham plastic is defined as having a yield value f which is larger than zero therefore, f will certainly be larger than r in the center and probably so near the center of the capillary. Hence, that such a material, when sheared in a capillary, can never flow in the center and tends to form a plug_at the center of the capillary. Therefore, the flow curve will only approach a straight line asymptotically and only at rather high shearing stresses. In many cases the flow curve is nonlinear over the complete measured range and therefore C• must differ from 1. Buck- ingham (3) set up an equation for the flow of Bingham plastics in capillary tubes, which can be used to calculate the plastic viscosity and yield value. However, the calculation is not as simple as that from the rotational vis- cometer flow curve. In addition, if the flow curve is very nonlinear, the material might be interpreted as having pseudoplastic flow behavior, even though its flow curve, if measured on a rotational viscometer, would be that of a Bingham plastic. Pseudoplastic and Dilatant In both the rotational and the capillary viscometers, the flow curves of a pseudoplastic and a dilatant material, Fig. 1, are nonlinear. The flow property most frequently determined for such materials is the apparent viscosity •, which is defined as •IG = rig (7) It is the inverse slope of a line drawn from any point of the flow curve to the origin of the coordinate system such as indicated in Fig. 1 by the dashed line in the diagram for the pseudoplastic flow curve. As indicated by the subscript G, the apparent viscosity is always shear dependent. The flow curves of these materials can be represented by an empirical relationship (4), G • •'¾ (8) In this relation N is called the structure number and N)i for pseudoplastic and N(1 for dilatant materials. The structure number N is obtained by plotting log G against log •-. If N is shear independent this plot is linear and N is the slope of this line. For many materials NG is shear dependent, but frequently different constant values of N can then be assigned to dif- ferent ranges of shear rate (1). These two flow properties, the apparent viscosity •/G and the structure number Na are required to describe the flow behavior of pseudoplastic and dilatant materials. Since either one or both flow properties are
604 JOURNAL OF THE SOCIETY OF COSMETIC CHEMISTS shear dependent, the factor C will differ from 1. In a rotational con- centric-cylinder viscometer C depends on Re, Rb and N and can be made negligibly small by proper design of the viscometer. In a capillary-tube viscometer the factor Cv depends on N only. The factors C for both types of viscometers are shown in Fig. 2, as a function of N (1). The dashed lines are for different ratios of Rc/Rb for the rotational viscometer. For instance, C will be less than 1.05, for N up to 7, if the cylinders are designed so that Rc/R, 50.925. The solid line is for the capillary-tube viscometer. Time-Dependent The three types of non-Newtonian materials described are frequently not only shear-dependent but also time-dependent. To determine if a material is time-dependent two flow curve measurements (where one can be obtained at increasing rates of shear and the other subsequently at decreasing rates of shear) have to be made on the same sample. Typical flow curves of a time-dependent material are shown in Figs. 1 and 3. Such up- and down-flow curves can be readily produced with a rotational
Purchased for the exclusive use of nofirst nolast (unknown) From: SCC Media Library & Resource Center (library.scconline.org)